Simultaneous Oxygen and pH Monitoring in Multidishes
OxoHydroDish OHD6
These 6-well multidishes have an oxygen and pH sensor integrated at the bottom of each well. They are delivered irradiated and pre-calibrated and are therefore ready-to-use. These SensorDishes? are read out with the SDR, which shows either the measured oxygen or pH values online, while the other parameter values are stored and can be analysed after data export.
- Ready-to-use
- Pre-calibrated
- Manual calibration possible
- Ideal for cell cultivation & tissue engineering
Technical
| Specifications | pH | Dissolved Oxygen |
|---|---|---|
| * at 37 °C in physiological solutions | ||
| Measurement range | 6.0 - 8.5 | 0 - 50 % O2 |
| Resolution* | ± 0.05 pH at pH = 7 | ± 0.4 % O2 at 20.9 % O2 |
| Precision* | ± 0.2 pH at pH = 7 (Sensor batch calibration) ± 0.1 pH at pH = 7 (Sensor spot calibration) | ± 1 % O2 at 20.9 % O2 |
| Drift* | < 0.1 pH within one week (sampling interval 10 min.) | < 0.2 % O2 within one week (sampling interval 10 min.) |
| Measurement temperature range | from + 15 to + 45 °C | from + 15 to + 45 °C |
| Response time* (t90) | at 25 °C: < 120 sec. | at 25 °C: < 30 sec. |
| Properties | ||
| Compatibility | Aqueous solutions, pH 2 - 10 | |
| Cross-sensitivity | Reduced to ionic strength (salinity); high concentration of small fluorescent molecules in the visible range can interfere | |
| Maximum filling volume | 15 mL | |
| Calibration | Pre-calibrated Disposables are delivered beta-irradiated | |
Related products
Resources
FAQs
Can I re-use the SensorDishes??
Can I use the SDR with other formats than the 24-well plates?
Do cells grow on the sensor inside the SensorDishes??
Do SensorDishes? come sterile?
How do I import data into excel from a text file containing measurement data?
How long can I use a SensorDish??
How long do I need to equilibrate before starting a SDR measurement?
I use the OxoHydroDish (OHD6) with the SDR. How do I see the values of both parameters (oxygen and pH) with the SDR software?
The SDR software shows "no sensor" instead of a value. What is the reason?
What is the time of delivery?
Which substances can interfere with the optical O2, pH and CO2 measurements?
Which toxicity tests where done with the SensorDish??
Why are there two different calibration data sets for SensorDishes??
Why do I need to equilibrate my samples for such long time periods before measurement with the SDR?
Why do I see peaks in the graphs of the SDR software (especially in the oxygen signal) when I open the incubator door / take the plates out of the incubator?
Why does the SDR software show pH<5, although I know that my sample is basic?